Excellent hmi touch screen supplier: The human-machine interface is the central link in the human-machine system, mainly by the safety engineering sub-discipline safety ergonomics to study and propose solutions based on the safety engineering equipment engineering, safety management engineering and safety systems engineering to study specific solutions and measures safety ergonomics. It realizes the conversion between the internal form of information and the acceptable form for human beings. See more info at switching power supply manufacturers.
Corresponding Functional Requirements: Gemerally, small plc have functions such as logic operation, timing and counting, which can be met for equipment that only needs to be controlled by switching quantity. For systems with switching control as the main and a small number of analog control, an enhanced plc with A/D and D/A conversion units and functions of addition and subtraction arithmetic operations and data transmission can be selected. For complex control, it is required to realized PID calculation, closed-loop control, communication networking and other functions, visual control scale and complexity, and choose mid-range or high-grade plc. However, medium and large PLC are more expensive and are generally used in large-scale process control and distributed control system.
Order principle: That is, in accordance with the order of processing events, access to view the order (such as from the whole to a single item, from large to small, from the top to the bottom, etc.) and control processes, such as the design of monitoring management and human-machine dialogue interface and its secondary interface. Functional principle: That is, according to the specific functional requirements of the object application environment and occasions, various subsystem control types, parallel processing requirements of the same interface of different management objects and simultaneous requirements of multiple dialogues, etc., the human-computer interaction interface is designed with multi-level menus, hierarchical prompt messages and multiple dialogues, so that users can easily distinguish and master the usage rules and characteristics of the interactive interface and improve its user friendliness and ease of operation.
The human factors to be considered in the analysis and design of human-machine interface mainly include the following: Human-computer matching: the user is a human being, the computer system as a human tool to complete the task, should make the computer and the human-computer system composed of a good match work; if there is a conflict, should let the computer to adapt to people, rather than people to adapt to the computer; Inherent human skills: As a computer user, people have many inherent skills. The analysis and synthesis of these abilities can help to estimate or judge the user’s ability to handle the complexity of the human-computer interface, and how much knowledge and help the user can get from the interface, as well as the time spent; Given this demand, future changes in the HMI will be in shape, in concept, and in application, thus bringing about a change in the core technology of industrial control machines. In general, the future development trend of HMI is six modernization: platform embedding, brand nationalization, equipment intelligence, interface fashion, communication network and energy saving and environmental protection.
Selecting HMI screen hardware parameters, mainly look at the CPU running speed and the capacity of the memory. According to the project involves the amount of data exchange animation, the size of the pictures to choose the CPU and memory. When processing more data and picture format is large, needing to choose a fast running speed, memory slightly large HMI. For example, Mochuan 15.6Inch MC-H156E, 7Inch MC-H070CWE, MC-H070CW with 1GHz CortexTM-A7 in CPU. And 10.1Inch MC-H100C, MC-H100CWE with 1GHz cortexTM-A7 and 4GB Flash memory. In addition, also needing to consider the functional requirements needed in the project, such as, how to achieve the multi-level tital pop-up, whether the screen display meets the customer’s need…etc.
In 2022, in order to meet the new needs of customers and the market, our MochuanDrives merged with a professional manufacturer of highly customized servo motors, with more than 20 years of experience in research and development, manufacturing and service of servo motors and brushless motors, especially good at tailor-made high-end motors with special specifications from scratch, until the stable manufacturing of large quantities. With NO MOQ, before large quantities needing to get 100% stable quality confirmation from our customers. Find extra information on mochuan-drives.com.
Why touch panel interface always fail to communicate with PLC? Common reasons why touchscreens do not communicate with PLCs 1. whether the correct communication protocol is selected (Modbus, Profibus, CANopen, etherCAT) 2. Is the communication line normal (RS232 rxd TXD GND RS485 a+B-CANopen CAN_L CAN_H CAN_GND ether cat network cable) 3. Whether the communication parameters are correct (station number, baud rate, parity bits) 4. Whether there is interference The program determines that the communication between HMI operator interface and plc has fialed
Multi-touch capacitive hmi panel is new design and very popular with the market. Why? It is similar the Apple iPone in our life. Becuase its flexible multi touch, very high transmittance, Glass+Glass, anti-scratching, no drifting, IPS full view TFT lcd, high resolution, brightness, high speed and easy flow, supporting animation formats. The color of multitouch HMI is rich and the picture displayed is more delicate. Why many people follows iPhone, just becuase it can bring the users different and beyond imagination experience. Same reasons, why this type panel hmi is very popular in European and American market, just becuase it can bring the project, equipment different experience then to obtain more high value market and to be easily competitive the competitors. Maybe a little try, but to bring a large value, so why not try.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.
At the same time, because the electrical room has the characteristics of complex data processing, many inverters, strong voltage interference, and closed space, the requirements for the configuration, stability, and anti-interference of the body are high. The industrial-grade control equipment can be well integrated into the electrical cabinet control equipment, and can effectively control all electrical equipment, in the current era of big data and the Internet of Things, and even directly through remote control equipment, the electrical cabinet equipment monitoring.