Best rated slitting line machine supplier: In terms of productivity, poor PQ can cause unscheduled downtime due to equipment malfunctions or system failures. This unpredictability can significantly disrupt operations, leading to lower productivity levels and potential revenue losses. Moreover, poor PQ can lead to diminished energy efficiency. Transformers operating under poor power quality conditions often require more power to function, leading to increased energy consumption and higher operating costs. The excess power demand could also strain the electrical grid, leading to further inefficiencies and disruptions. Additionally, the costs associated with repairing or replacing damaged equipment due to poor power quality can be substantial. There are also indirect costs to consider, such as those associated with investigation and troubleshooting of power quality issues. Discover more details on https://www.canwindg.com/products-20760.
How to deal with the failure of the main transformer cooler? The failure of the main transformer cooler may cause the temperature of the main transformer to rise, thereby affecting the normal operation of the transformer. Therefore, if it is found that the main transformer cooler is faulty, it is necessary to take timely measures to deal with it. Here are some possible approaches: Replacing Faulty Cooler Parts: If some parts in your cooler are damaged or malfunctioning, consider replacing those parts to restore the cooler to working properly. The specific operation needs to be carried out according to the structure of the cooler and the cause of the failure. Clean the cooler: If the pipes or cooling fins in the cooler are clogged or dirt accumulates, it may reduce the cooling effect and affect the normal operation of the transformer. The way of cleaning can be used to remove the dirt and sundries inside the cooler to restore the normal operation of the cooler.
What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.
The company mainly produces 150 model oil-type transformercore shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage transformer tc. CANWIN hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.
As one of the best electrical equipment manufacturers & suppliers in China,Canwin specialized in transformer electrical equipment, our electrical equipment including cut to length lines, slitting lines and foil winding machines manufacturing.Electrical equipment mainly used as the iron core of various motors, generators and transformer equipment.Electrical equipment manufacturers and suppliers are currently focusing on sustainability, as global power grids must be updated to accept new forms of renewable energy, as well as IoT and enhanced communications platforms. Regardless of the specific application, electrical equipment is paired with detailed instructions for installation & maintenance and is supported by customer support services to ensure that the machine works as intended.
Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.
The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.
The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. See additional info on https://www.canwindg.com/
Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.
As a professional energy storage system manufacturer, Canwin specialized in battery energy storage system and containerized energy storage system manufacturing. An energy storage system, often abbreviated as ESS, is a device or group of devices assembled together, capable of storing energy in order to supply electrical energy at a later time. In the energy storage systems, the lithium energy storage battery only interacts with the energy storage converter at high voltage, and the converter takes power from the AC grid to charge the battery pack. Or the battery pack supplies power to the converter, and the electric energy is converted into AC by the converter and sent to the AC power grid.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.