Coriolis flow meters manufacturer right now: Differences Between coriolis vs magnetic flow meter – While both mass flow meters and magnetic flow meters are used to measure the flow of fluids, there are several key differences between the mass flow meter vs magnetic flow meter: Accuracy: Both mass flow meters and magnetic flow meters are known for their accuracy. But mass flow meters are generally considered to be more accurate, especially in applications where the temperature or pressure may vary. Compatibility: Mass flow meters are compatible with a wide range of fluids, including gases, liquids, and slurries. Magnetic flow meters, on the other hand, are only suitable for conductive fluids. Find more details on turbine mass flow meter.
There are many advantages to use: Nowadays, there are many choices of measurement tools, so they have attracted the attention of the public. It is precisely because of this that the emergence of natural gas turbine flow meters has also provided a lot of support to many industries. After use, it can mainly provide the advantages of convenient installation, high reliability, intuitive and clear data, and accurate measurement results. Description of the measuring medium: There are many types of tools that can be used now, all of which can be launched according to the needs of the industry, and the effect of using them is also very stable. Nowadays, the application frequency of gas turbine flow meters is also very high, mainly for gas and liquid measurement, using temperature and pressure to complete the measurement process, which is worthy of attention.
It is the existence of domestic brands that has forced the prices of foreign brands to drop by 1/2-2/3 in recent years. The production and R&D investment of natural gas turbine meter is relatively large, and the prices of enterprises with certain strength will also be higher in domestic brands. But even then, they are only about half the price of high-end international brands. Therefore, it is recommended that users choose carefully on the basis of comprehensive consideration of their respective use requirements and procurement costs. Don’t pursue low prices too much, nor do you need to pursue imported brands inappropriately.
Beijing Sincerity Automatic Equipment Co., Ltd is a research and development center, focusing only on one type of flow meter, the Coriolis mass flow meter, which has been in use for 33 years. Our Coriolis mass flow has reached the international leading level. We provide three types of Coriolis mass flowmeters, including U-shaped, micro-bent V-shaped and triangular, to meet the different needs of different industries. We can provide coriolis flow meter with ultra high pressure of 100MPa, ultra high temperature of 350 C, and minimum temperature of -300 C. We can also measure ultra-high viscosity liquids, such as 70,000 cps glue. We have been very successful with gas measurements such as hydrogen. In addition, we have been very successful in two-phase / three-phase / multiphase flow liquid measurement. We support OEM services. You can even customize the internal software for Coriolis mass flow meters. We also support market agents. Find extra info on https://www.bjssae.com/.
Sincerity, excellence in coriolis flow meter production with 33 years experience, Since 1987.Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China.Our products including coriolis mass flow meter,thermal mass flow meter,fork density meter and etc.We have 100+ workers and 5000+ factory,our customers from all over the world. We support OEM coriolis mass flow meter name plates.
It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.
China Capital technology group invested in the SINOPEC automation instrument department of Beijing institute of chemical industry. Beijing shouke shí huà automatic equipment Co., LTD (Beijing Sincerity’s predecessor) was officially established. “Shí huà” is the Chinese words from SINOPEC. Sincerity officially switched from a national company to joint-stock company. Beijing shouke shí Huá ( which is Beijing Sincerity Automatic Equipment Co., Ltd now ) was officially established. The Chinese pronunciation of “shí Huá “ and “ shí huà” are very close to each other. The 1st generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are with all discrete components, little chips and LED digital display.